Insulin Clinics / Monitoring and safety

Monitoring blood glucose

A glucose number on its own is not the goal. The goal is patterns: where you sit most of the time, where you spike, and where you go low.

Last updated: October 2026 · Based on ADA Standards of Care, FDA prescribing information, and NIDDK · General information, not medical advice — see our editorial policy

If this is an emergency — severe low blood sugar, vomiting with high blood sugar, confusion, or trouble breathing — call your local emergency number now. This site is reference information, not medical advice.

Fingerstick meters

A blood glucose meter measures glucose in a drop of blood from a fingertip. The hardware is mature and inexpensive. Test strips are the consumable cost.

How to get an accurate reading:

Meters sold today must meet accuracy standards (roughly within 15 percent of a lab value for most readings), which is good enough for treatment decisions. If a reading does not match how you feel, recheck before acting on it.

Continuous glucose monitors (CGMs)

A CGM is a small sensor — usually worn on the back of the upper arm or the abdomen, depending on the device — with a tiny filament under the skin that measures glucose in interstitial fluid (the fluid between cells). It reads continuously and sends a number to a phone, smartwatch, receiver, or insulin pump every 1–5 minutes.

How CGMs work

Interstitial glucose lags behind blood glucose by about 5–15 minutes, depending on how fast glucose is changing. When glucose is steady, the two values are very close. When glucose is rising or falling fast (after a meal, after rapid insulin, during exercise), the CGM reads slightly behind the actual blood value. Modern CGMs use software to predict where glucose is heading and partially correct for this lag.

Major systems available now include the Dexcom G7 and G7 15 Day, Abbott FreeStyle Libre 3 Plus and Libre 2 Plus (which replaced the original Libre 2 and Libre 3 sensors in the U.S. in 2025), the Medtronic Guardian 4 and Simplera sensors, and the implantable Eversense 365. Sensors worn on the skin last about 7 to 15 days depending on the device; the implantable sensor lasts up to a year. Most current sensors do not require fingerstick calibration in normal use.

What CGMs add

Access

CGM coverage in the United States has expanded significantly. As of 2026, Medicare covers CGMs for people who use any insulin, and for some people not on insulin who have problematic hypoglycemia; many commercial plans cover CGMs for people on insulin, though rules vary by plan. Some over-the-counter sensors are sold without a prescription but are intended for people who do not use insulin — if you take insulin, use a prescription CGM that is cleared for insulin dosing decisions.

A1C: what it actually measures

A1C (also called HbA1c or glycated hemoglobin) is a blood test that measures the percentage of hemoglobin molecules in red blood cells that have glucose stuck to them. Because red blood cells live about 3 months, A1C reflects average glucose over roughly the previous 8–12 weeks, with more weight on the most recent month.

A1CEstimated average glucose
5.7%~117 mg/dL
6.5%~140 mg/dL
7.0%~154 mg/dL
8.0%~183 mg/dL
9.0%~212 mg/dL
10.0%~240 mg/dL

What A1C does and does not show

A1C is excellent at summarizing whether you are running high or low on average over months. It is the strongest predictor of long-term complication risk, and most clinical guidelines target an A1C below 7 percent for many adults — sometimes higher (7.5–8 percent) for older adults or people at high risk of severe hypoglycemia, sometimes lower for younger adults or in pregnancy.

What A1C does not show:

Time in range

Time in range (TIR) is the percentage of time CGM readings sit within a target glucose range — for most adults, 70 to 180 mg/dL (3.9 to 10.0 mmol/L).

Standard targets endorsed by the international consensus on time in range:

For older adults at higher risk of low blood sugar, slightly looser targets are common (more than 50 percent in range, less than 1 percent below 70, and less than 10 percent above 250). For pregnancy with type 1 diabetes, targets are tighter (70 percent in 63–140 mg/dL, less than 4 percent below 63).

Time in range is increasingly used by clinicians because it captures both the average and the variability — a 70 percent TIR usually means a steadier life than the same A1C with worse range data. Most CGM platforms generate a standard report (the Ambulatory Glucose Profile, or AGP) that shows TIR alongside a typical 24-hour pattern.

How often to check

The right number depends on the regimen:

Type 2 diabetes on basal insulin only

Type 2 diabetes on basal-bolus, or any type 1 diabetes

Special times to check more

What patterns to look for

The most useful question is rarely "is this number good?" — it is "is this happening repeatedly?"

Most patterns become visible only when you look at 7–14 days at once. CGM reports do this automatically; if using a meter, an honest week of logging is more useful than scattered checks over a month.

A reading that does not match how you feel deserves a recheck, not a reaction. Meter and CGM errors do happen — wash hands, recheck on a different finger, and confirm before treating an unexpected number, especially before adding a correction dose.

Frequently asked questions

What is a normal blood sugar for someone on insulin?

Targets are individual, but for many non-pregnant adults the ADA suggests 80–130 mg/dL (4.4–7.2 mmol/L) before meals and under 180 mg/dL (10.0 mmol/L) 1–2 hours after starting a meal, with an A1C under 7 percent. Older adults and people prone to lows often have looser targets. Ask your care team what your targets are.

How accurate is a CGM compared with a fingerstick?

CGMs read glucose in the fluid under the skin, which lags blood glucose by about 5–15 minutes when levels are changing quickly. If a CGM reading does not match how you feel, or before treating an unexpected number, confirm with a fingerstick.

How often is A1C checked?

Usually every 3 months when treatment is changing or targets are not being met, and about twice a year when things are stable.

What does time in range mean?

It is the share of the day your CGM readings spend between 70 and 180 mg/dL. Most adults aim for 70 percent or more, with less than 4 percent below 70 and less than 1 percent below 54.